电池测试系统 _ 循环测试


Project Description
Cell Cycler

Key Features

  • Multi-current range: Up to 4
  • Output Accuracy: ±0.05% F.S
  • High Frequency Switching Type
  • Aux. temp sensing: 2point/Ch
  • Easy Maintenance
  • Current Rising/Falling: ≤2ms
  • Data sampling: ≥1ms
  • High Efficiency (Two Stage Conversion)
Specification

Item

Spec.

Voltage
(V)
Range -5~5V
Resolution 16bit
Accuracy ±0.05% of Full Scale
Current
(A)
Range Max.±500A (Parallel Max. ±1000A)
Resolution 18bit
Accuracy ±0.05% of Full Scale
Rising/Falling ≤2ms (10~90%)
Operating Mode CC, CC/CV, CP, CP/CV, Pattern, DCIR, HPPC
Protection OVP, OCP, OT, EMG S/W
Temperature Sensing 2point per Ch
Operating Noise ≤65dB
Network RS-232, RS-485, Ethernet, CAN, LIN, JTAG
Cooling Method Forced Air Cooling
Energy Efficiency ≥87%
Line Up

Model

Voltage
(V)

Current
(A)

Channel

Power
(kW)

Dimension
(WxDxHmm)

BCS51H 0~5V ±100A 24 12 600x800x2100
(19” Rack)
BCS52H ±200A 24 24
BCS53H ±300A 16 24
BCS54H ±400A 12 24
BCS55H ±500A 16 40 1600x800x1650
BCS56H ±600A 16 48
BCS57H ±700A 8 28
BCS58H ±800A 8 32
BCS59H ±900A 8 36
BCS51K ±1000A 8 40
Module Cycler

Key Features

  • Series/Parallel Operation Support
  • On line Mode Support
  • High Accuracy: ±0.05% F.S
  • Interlinked w/ BMS CAN Interface
  • Battery & Road Simulation Support
  • High Frequency Switching Type
  • Easy Maintenance
  • Current Rising/Falling: ≤2ms
  • Data sampling: ≥1ms
  • High Efficiency (Two Stage Conversion)
Specification

Item

Spec.

Voltage
(V)
Range Max. 400V
Resolution 18bit
Accuracy ±0.05% of Full Scale
Current
(A)
Range Max.±1000A
Resolution 18bit
Accuracy ±0.05% of Full Scale
Rising/Falling ≤2ms (10~90%)
Parallel Max. ±2000A (4P)
Operating Mode CC, CC/CV, CP, CP/CV, Pattern, DCIR, HPPC
Sampling Rate ≥1ms
Protection OVP, OCP, OT, EMG S/W
DAQ Aux. Voltage: up to 200Ch
Au. Temp. Sensing: up to 200Ch
Operating Noise ≤65dB
Network RS-232, RS-485, Ethernet, CAN, LIN, JTAG
Cooling Method Forced Air Cooling
Energy Efficiency ≥92%
Line Up

Model

Voltage
(V)

Current
(A)

Power
(kW)

Dimension
(WxDxHmm)

BMT-50 50V ±100/200/300/400A 5/10/15/20 600x800x1800
BMT-150 150V 15/30/45/60
BMT-200 200V 20/40/60/80
BMT-300 300V 30/60/90/120
BMT-400 400V 40/80/120/160
Pack Cycler

Key Features

  • Series/Parallel Operation Support
  • On line Mode Support
  • Driving Simulation Support
  • Output Accuracy: ±0.05% F.S
  • Interlinked w/ BMS CAN Interface
  • Battery & Road Simulation Support
  • High Frequency Switching Type
  • Compact Size/Easy Maintenance
  • Current Rising/Falling: ≤2ms
  • Data sampling: ≥1ms
  • High Efficiency (Two Stage Conversion)
Specification

Item

Spec.

Voltage
(V)
Range Max. 1500V
Resolution 18bit
Accuracy ±0.05% of Full Scale
Current
(A)
Range Max.±1000A
Resolution 18bit
Accuracy ±0.05% of Full Scale
Rising/Falling ≤2ms (10~90%)
Parallel Max. ±2000A (2P)
Operating Mode CC, CC/CV, CP, CP/CV, Pattern, DCIR, HPPC
Sampling Rate ≥1ms
Protection OVP, OCP, OT, EMG S/W
DAQ Aux. Voltage: up to 200Ch
Au. Temp. Sensing: up to 200Ch
Operating Noise ≤65dB
Network RS-485, Ethernet, CAN, CAN FD, LIN
Cooling Method Forced Air Cooling
Energy Efficiency ≥90%
Line Up

Model

Voltage
(V)

Current
(A)

Channel

Power
(kW)

Dimension
(WxDxHmm))

BPT-500 500V Up to
±1000A
4 Max.
500kW/Ch
1MW/Rack
2100x1000x2000
BPT-600 600V 4
BPT-800 800V 2
BPT-1000 1000V 2
BPT-1200 1200V 2
BPT-1500 1500V 2